S. Idler Replacement
1. Remove the brake by following steps 1-14 of the removal section of the
brake replacement procedure.
2. Using a 9/16” socket, remove the nut and lock washer holding the idler to
the monocoque. This is located on the right outer side of the monocoque.
3. Remove the bolt that runs through the center of the idler.
4. Insert the bolt through the new idler and back into mounting hole.
5. Install the lock washer and nut onto the idler mounting bolt. Tighten nut.
6. Reinstall the brake assembly by following steps 1-5 in the installation
section of the brake replacement procedure.
T. Foot Pad Replacement
1. Locate and remove the four (4) bolts and washers under the black foot
pad mounting plate, using a 7/16” socket. (This is the plate the foot pad
(A1489) mounts to.) Only the older units had bolts. Newer units do not.
2. Pull the old foot pad off. It is held on with super glue.
3. Clean the mounting surfaces with isopropyl alcohol.
4. Apply ten (10) beads of quick setting Super Glue to different areas of the
black plate the foot pad mounts to. See the drawing for super glue drop
locations.
5. Set the new foot pad in place.
6. Apply pressure to the top side of the foot pad for approximately 30-45
seconds to let the Super Glue set.